Section 5 – Procedures
12 Volts
02 WHT
Pin 27
24 BLU/BLK
Pin 17
23 BLK/WHT
Pin 18
OCM
12 Volts  
Left Steer 
Selected
04 RED/YEL
02 WHT
R RED/GRN
Pin  30
OCM
12 Volts
229044ADA
152
Drive (A2) Controller 
04 YEL
POWER
RED
GROUND
BLK
BLK
D‐SIGNAL
YEL
LEFT
WHT/RED
RIGHT
WHT/YEL
12 Volts 
Right Steer 
Selected
Riser (A3) Controller
POWER
RED
GROUND
BLK
R‐SIGNAL
YEL
Neutral Position = 4.2 ‐ 4.8 Volts
Forward = 4.9 ‐ 8.5 Volts @ full stroke
Reverse = 4.1 ‐ 0.5 Volts @ full stroke
Drive Forward
Drive Reverse
Neutral Position = 4.2 ‐ 4.8 Volts
Forward = 4.9 ‐ 8.5 Volts @ full stroke
Reverse = 4.1 ‐ 0.5 Volts @ full stroke
Reference
Analog Input
AI 4
RiserDown
Platform
Neutral 
Position    
4.2 ‐ 4.8 
Volts
Reference
Analog Input
AI 1
Riser Up
Neutral 
Position     
4.2 ‐ 4.8 
Volts
SJ85 AJ