Skyjack SJ85 AJ Service Manual page 178

Articulating boom
Hide thumbs Also See for SJ85 AJ:
Table of Contents

Advertisement

Section 5 – Procedures
5.6-6 Deutz TD2.9L Fault Codes
Code SPN FMI Blink Code
916
523721
2
917
523721
2
918
523981
11
919
523330
14
920
523330
14
921
523330
14
922
523330
14
923
523330
14
925
523720
8
926
523720
8
927
523721
11
928
523722
8
929
523722
8
930
523721
8
931
523721
8
932
29
3
935
91
3
937
29
4
940
91
4
942
523921
3
943
3532
3
944
523921
4
946
1079
13
947
1080
13
948
523601
13
956
677
3
957
677
4
958
677
5
959
677
12
960
677
3
961
677
4
965
523922
3
969
624
5
229044ADA
182
6-8-9
Sensor DEF supply module temperature; plausibility error (normal condition).
Sensor DEF supply module temperature; plausibility error (cold start
6-8-9
condition).
SCR plausibility, OBD and diagnosis; Stuck in range check of DEF tank
2-4-3
temperature sensor.
DEF-tank without heating function (heating phase).
1-3-1
Immobilizer status; fuel blocked.
1-3-1
DFC to block the fuel by Sia. No detailed information!
DFC to indicate that TEN-code or UC-code received if ECU is learned.
1-3-1
No detailed information!
1-3-1
DFC to indicate that no code is received via CAN. No detailed information!
1-3-1
DFC to indicate that wrong code is received. No detailed information!
1-4-8
DEF supply module heater temperature; duty cycle in failure range.
1-4-8
DEF supply module heater temperature; duty cycle in invalid range.
6-8-9
Urea supply module temperature measurement not available.
6-9-1
DEF supply module PWM signal; period outside valid range.
6-9-1
Detect faulty PWM signal from Supply Modul.
6-8-9
DEF supply module temperature; duty cycle in failure range.
6-8-9
Urea supply module temperature; duty cycle in invalid range.
1-2-6
Handthrottle idle validation switch; short circuit to battery
2-2-6
Sensor error accelerator pedal. signal range check high.
1-2-6
Handthrottle; short circuit to ground.
2-2-6
Sensor error accelerator pedal. Signal is below the range.
7-1-4
Sensor error burner temperature; signal range check high.
1-2-7
Sensor error DEF tank level; signal range check high.
7-1-4
Sensor error burner temperature; signal range check low.
2-8-2
Failure of sensor supply voltage 1.
2-8-2
Failure of sensor supply voltage 2.
2-8-2
Failure of sensor supply voltage 3.
5-1-2
Starter relay high side. Short circuit to battery.
5-1-2
Starter relay high side short circuit to ground.
5-1-2
Starter relay low side no load error.
5-1-2
Starter relay powerstage over temperature.
5-1-2
Starter relay low side short circuit to battery.
5-1-2
Starter relay low side short circuit to ground.
7-1-5
Burner shut of valve; short circuit to battery.
5-1-3
SVS lamp; open load.
Error Identification
Deutz Diesel Engines
1513AA-12
SJ85 AJ

Advertisement

Table of Contents
loading

Table of Contents