Floor Loading Pressure - Skyjack SJ85 AJ Service Manual

Articulating boom
Hide thumbs Also See for SJ85 AJ:
Table of Contents

Advertisement

Table

2.9 Floor Loading Pressure

Model
SJ85 AJ ANSI/CSA
SJ85 AJ CE
SJ85 AJ AS
Gross Aerial Platform Weight = Weight + platform capacity
LCP – Locally Concentrated Pressure – is a measure of how hard the aerial platform tire tread presses on
the area in direct contact with the floor. The floor covering (tile, carpet, etc.) must be able to withstand more
than the indicated values above.
OUP – Overall Uniform Pressure – is a measure of the average load the aerial platform imparts on the
whole surface projected directly underneath it. The structure of the operating surface (beams, etc.) must
be able to withstand more than the indicated values above.
The welder option will add approximately 350 lb (158.8 kg) to total aerial platform weight and 175 lb (79.4
kg) to max. wheel load.
NOTE:
The LCP or OUP that an individual surface can withstand varies from structure to structure and is generally
determined by the engineer or architect for that particular structure.
Locally Concentrated Pressure (LCP)
Foot Print Area identified by test
Wheel Load
LCP =
Foot Print Area
Foot Print Area
229044ADA
40
Gross Aerial
Platform Weight
36,300 lb
16 465 kg
16 965 kg
16 465 kg
Total Aerial Platform Load
Wheel
16,535 lb
7500 kg
1179 kPa
7500 kg
1179 kPa
7500 kg
1179 kPa
Overall Uniform Pressure (OUP)
Base Area = Length x Width
Weight of MEWP + Capacity
OUP =
LCP
OUP
171 psi
355 psf
17 kPa
17.5 kPa
17 kPa
Base Area
Base Length
1766AA
Base Width
SJ85 AJ

Advertisement