Skyjack SJ85 AJ Service Manual page 183

Articulating boom
Hide thumbs Also See for SJ85 AJ:
Table of Contents

Advertisement

Deutz Diesel Engines
5.6-6 Deutz TD2.9L Fault Codes
Code SPN FMI Blink Code
1341
524035
12
1342
524036
12
1345
524069
9
1357
524052
11
1368
524052
11
1378
523919
2
1379
523920
2
1380
3253
2
1381
164
2
1389
523922
5
1390
523922
12
1392
523922
4
1395
523921
2
1398
1136
0
1402
4769
2
1403
4769
2
1411
1188
11
1412
1188
11
1413
1188
13
1414
1188
2
1415
1188
7
1417
1188
11
1418
1188
11
1423
51
0
1424
51
1
1425
172
0
1431
524028
2
1432
524029
2
1436
524034
5
1437
524034
12
1438
524034
3
SJ85 AJ
5-5-5
Injector diagnostics; time out error in the SPI communication.
5-5-5
Injector diagnostics Slave; time out error in the SPI communication.
Timeout Error of CAN-Receive-Frame MSMon_FidFCCTO; Master-Slave CAN
8-9-6
communication faulty.
8-3-6
Error memory Slave reports FID MSMonFC2 (collective error).
8-3-6
Error memory Slave reports FID MSMonFC3 (collective error).
6-9-4
Sensor air pump airpressure; plausibility error.
7-1-6
Sensor exhaust gas back pressure burner; plausibility error.
6-9-2
Sensor differential pressure (DPF); plausibility error.
8-3-9
Rail pressure safety function is not executed correctly ().
7-1-5
Burner Shut Off Valve; open load.
7-1-5
Burner Shut Off Valve; powerstage over temperature.
7-1-5
Burner Shut Off Valve; short circuit to ground.
Burner temperature sensor; Plausibility Check for burner temperature sensor
7-1-4
Sensor burner temperature; plausibility error.
6-8-1
Physical range check high for ECU temperature.
Sensor exhaust gas temperature OxiCat downstream (normal operation);
6-8-4
plausibility error.
Sensor exhaust gas temperature OxiCat downstream (regeneration);
6-8-4
plausibility error.
8-1-4
Wastegate actuator; internal error.
8-1-4
Wastegate actuator; EOL calibration not performed correctly.
8-1-4
Wastegate actuator calibration deviation too large, recalibration required.
8-1-4
Wastegate; status message from ECU missing.
8-1-4
Wastegate actuator; blocked.
8-1-4
Wastegate actuator; over temperature (> 135°C).
8-1-4
Wastegate actuator; operating voltage error.
Warning threshold for an internal actuator error exceeded, < 4L EGR.
5-9-4
actuator und >4L Air Intake Flap.
Shut off threshold for an internal actuator error exceeded, < 4L EGR.actuator
5-9-4
und >4L Air Intake Flap.
2-2-6
air temperature within air filter box above maximum physical value.
8-1-5
CAN message PROEGRActr; plausibility error.
Timeout Error of CAN-Receive-Frame ComEGRActr - exhaust gas
8-1-5
recirculation positioner.
8-1-6
Disc separator; open load.
8-1-6
Disc separator; powerstage over temperature.
8-1-6
Disc separator; short circuit to battery.
Error Identification
Section 5 – Procedures
1513AA-17
229044ADA
187

Advertisement

Table of Contents
loading