Deutz Diesel Engines
5.6-6 Deutz TD2.9L Fault Codes
Code SPN FMI Blink Code
578
523759
14
579
523760
14
580
651
3
581
652
3
582
653
3
583
654
3
584
655
3
585
656
3
590
655
4
591
656
4
592
523615
5
593
523615
12
594
523615
3
595
523615
4
596
523615
3
597
523615
4
598
523615
3
599
523615
4
605
1323
12
607
1323
12
608
1323
12
609
1323
12
610
1322
12
611
1346
0
612
523612
12
613
523612
12
614
523612
12
615
523612
12
616
523612
12
617
523612
12
618
523612
12
619
523612
12
620
523612
12
621
523612
12
623
523612
12
SJ85 AJ
1-6-2
Special pattern for special cases No detailed information!
1-6-3
Special pattern for special cases No detailed information!
154
Injector 1 (in firing order): Short circuit.
155
Injector 2 (in firing order): Short circuit.
156
Injector 3 (in firing order): Short circuit.
161
Injector 4 (in firing order): Short circuit.
162
Injector 5 (in firing order): Short circuit.
163
Injector 6 (in firing order): Short circuit.
1-6-2
High side to low side short circuit in the injector 5 (in firing order).
1-6-3
High side to low side short circuit in the injector 6 (in firing order).
135
Metering unit (Fuel-System): Open load.
135
Metering unit (Fuel-System): Powerstage over temperature.
135
Metering unit (Fuel-System): Short circuit to battery, highside.
135
Metering unit (Fuel-System): Short circuit to ground, high side.
135
Metering unit (Fuel-System): Short circuit to battery, low side.
135
Metering Unit (Fuel-System): Short circuit to ground, low side
1-3-5
Metering unit, short circuit to battery.
1-3-5
Metering unit, short circuit to ground.
2-4-1
Too many recognized misfires in cylinder 2 (in firing order).
2-4-1
Too many recognized misfires in cylinder 4 (in firing order).
2-4-1
Too many recognized misfires in cylinder 5 (in firing order).
2-4-1
Too many recognized misfires in cylinder 6 (in firing order).
2-4-1
2-4-1
Misfire detection monitoring No detailed information!
555
Internal ECU monitoring detection reported error.
ECU reported internal software error.
555
Internal ECU monitoring detection reported error.
555
ECU reported internal software error.
555
ECU reported internal software error.
555
ECU reported internal software error.
555
ECU reported internal software error.
555
ECU reported internal software error.
555
Injection system,electrical error injectors.
555
ECU reported internal software error.
555
ECU reported internal software error.
555
ECU reported internal software error.
Error Identification
Section 5 – Procedures