10 Platform Control Console; 11 Testing Platform Emergency Stop Button And Platform Emergency Stop Light; 12 Verifying Load Sensing Module Self-Check - Skyjack SJ85 AJ Operating Manual

Hide thumbs Also See for SJ85 AJ:
Table of Contents

Advertisement

Function Tests
Platform control
console
Fall protection
anchorages

4.3-10 Platform control console

WARNING
Ensure that you maintain three points of contact to
mount/dismount platform.
1. Ensure both emergency stop buttons at base
and platform are pulled out.
2. On base control console, turn off/base/platform
key switch to platform position.
3. Enter platform and close gate/drop bar.
WARNING
DO NOT operate any control on platform control
console without proper fall protection secured to
designated location in platform. Failure to avoid
this hazard could result in death or serious injury.
WARNING
Ensure that there are no personnel or obstructions
in test area and that there is sufficient room for
boom to swing.
SJ85 AJ
Emergency
stop
Footswitch
4.3-11 Testing platform emergency stop
button and platform emergency
stop light
1. Ensure engine is running.
2. Push in emergency stop button and attempt to
operate any MEWP function.
Result: Engine should shut down and MEWP
functions should not operate.
3. Pull out emergency stop button and restart
engine.
Result: Emergency stop light should
continuously illuminate.
4.3-12 Verifying load sensing module self-
check
1. Push in emergency stop button.
2. Pull out emergency stop button.
Result: After four seconds of time elapses, the
red light and audible alarm pulse two times.
This indicates the system is active and there
are no faults.