Section 5 – Procedures
5.6-6 Deutz TD2.9L Fault Codes
Code SPN FMI Blink Code
1264
523922
7
1285
524038
9
1286
524039
9
1287
524040
9
1288
524041
9
1289
524042
9
1290
524043
9
1291
524045
9
1292
524046
9
1293
524047
9
1294
524048
9
1299
523788
0
1300
523788
0
1302
524024
11
1324
523995
13
1325
523996
13
1326
523997
4
1327
523998
4
1328
523999
12
1329
524000
5
1330
524001
5
1333
524000
3
1334
524001
3
1337
2797
4
1338
2798
4
1339
2797
4
1340
2798
4
229044ADA
186
8-5-5
Burner Shut Off Valve; blocked open.
Timeout error of CAN-Receive-Frame ComMS_Sys1TO (error memory Slave);
8-2-4
Master-Slave internal CAN message.
Timeout error of CAN-Receive-Frame ComMS_Sys2TO (error memory Slave);
8-2-5
Master-Slave internal CAN message.
Timeout error of CAN-Receive-Frame ComMS_Sys3TO (error memory Slave);
8-2-6
Master-Slave internal CAN message.
Timeout error of CAN-Receive-Frame ComMS_Sys4TO (error memory Slave);
8-2-7
Master-Slave internal CAN message.
Timeout error of CAN-Receive-Frame ComMS_Sys5TO (error memory Slave);
8-2-8
Master-Slave internal CAN message.
Timeout error of CAN-Receive-Frame ComMS_Sys6TO (error memory Slave);
8-2-9
Master-Slave internal CAN message.
Master Slave, Error of message counter CAN receive message
8-3-1
ComMSMoFOvR; ComMSMoFOvR1CNT.
8-3-2
Master-Slave CAN; Error Checksum of CAN-Receive Message.
Master-Slave CAN; Error of message length of CAN receive message
8-3-3
ComMSMoFOvR;_ComMSMoFOvR1DLC.
8-3-4
Timeout error CAN message ComMSMoFOvR1TO error memory Slave.
6-5-5
Wastegate plauisibility error off CAN transmit message.
6-5-5
Timeout Error of CAN-Receive-Frame ComTrbChActr; Wastegate.
Deviation of the exhaust gas temperature setpoint to actual value
8-6-6
downstream (DOC) too high.
Check of missing injector adjustment value programming (IMA) injector 7 (in
7-9-5
firing order).
check of missing injector adjustment value programming (IMA) injector 8 (in
7-9-6
firing order).
7-9-7
Injector cylinder bank 1 slave; short circuit.
7-9-8
Injector cylinder bank 2 slave; short circuit.
7-9-9
Injector powerstage output Slave defect.
1-7-7
Injector 7 (in firing order); interruption of electric connection.
1-7-8
Injector 8 (in firing order); interruption of electric connection.
1-7-7
Injector 7 (in firing order); short circuit.
1-7-8
Injector 8 (in firing order); short circuit.
Timeout of Short-Circuit Ground Diagnosis Cyl. Bank 0;_
5-6-5
IVDiaShCirGndToutBnk_0.
Timeout of Short-Circuit Ground Diagnosis Cyl. Bank 1;_
5-6-6
IVDiaShCirGndToutBnk_1.
5-6-5
Injector diagnostic; Short circuit to ground cylinder bank 0.
5-6-6
Injector diagnostic; Short circuit to ground cylinder bank 1.
Error Identification
Deutz Diesel Engines
1513AA-16
SJ85 AJ