Skyjack SJ85 AJ Service Manual page 174

Articulating boom
Hide thumbs Also See for SJ85 AJ:
Table of Contents

Advertisement

Section 5 – Procedures
5.6-6 Deutz TD2.9L Fault Codes
Code SPN FMI Blink Code
624
523612
12
625
523612
12
627
523612
12
628
523612
12
629
523612
12
630
523612
12
631
523612
12
632
523612
12
633
523612
12
634
523612
12
635
523612
12
636
523612
12
637
523612
12
638
523612
12
639
523612
12
640
523612
12
641
523612
12
642
523612
12
643
523612
12
644
523612
3
646
523612
4
648
523008
1
649
523008
2
654
2634
12
656
2634
12
659
3226
2
692
523752
0
693
523752
0
714
523612
12
715
523612
12
716
523612
12
717
523612
12
229044ADA
178
555
ECU reported internal software error.
555
ECU reported internal software error.
555
ECU reported internal software error.
555
ECU reported internal software error.
555
Diagnostic fault check to report the accelerator pedal position error.
555
Diagnostic fault check to report the engine speed error.
555
Error in the plausibility of the injection energizing time.
555
Error in the plausibility of the start of energising angles.
555
Diagnostic fault check to report the error due to non plausibility in ZFC.
Diagnosis fault check to report the demand for normal mode due to an error
555
in the PoI2 quantity.
Diagnosis fault check to report the error to demand for an ICO due to an
555
error in the PoI2 shut-off.
Diagnosis fault check to report the error to demand for an ICO due to an
555
error in the PoI3 efficiency factor.
555
Internal ECU monitoring detection reported error.
555
Monitoring of Fuel Quantity Correction.
Diagnostic fault check to report the plausibility error in rail pressure
555
monitoring.
555
Diagnostic fault check to report the error due to torque comparison.
555
Diagnosis of curr path limitation forced by ECU monitoring level 2.
555
Diagnosis of lead path limitation forced by ECU monitoring level 2.
5-5-5
Diagnosis of set path limitation forced by ECU monitoring level 2.
5-5-5
Reported Over Voltage of Supply.
5-5-5
Reported UnderVoltage of Supply.
4-2-4
Manipulation control was triggered.
4-2-4
Timeout error in Manipulation control.
7-5-7
Early opening defect of main relay No detailed information!
7-5-7
DFC for stuck main relay error No detailed information!
8-1-3
Nox feed back fault detection No detailed information!
7-5-8
Plausibiliti error during Rich to Lean switch over No detail informationen!
7-5-8
Monitoring of Nox signal readyness No detail informationen!
Diagnostic fault check to report WDA active due to errors in query-/response
5-5-5
communication.
5-5-5
Diagnostic fault check to report ABE active due to undervoltage detection.
5-5-5
Diagnostic fault check to report ABE active due to overvoltage detection.
5-5-5
Diagnostic fault check to report WDA/ABE active due to unknown reason.
Error Identification
Deutz Diesel Engines
1513AA-8
SJ85 AJ

Advertisement

Table of Contents
loading

Table of Contents