Figure 3-11: Correct Position Of Probe Lock Plate; Figure 3-12: Enlarging Mounting Plate Hole - Honeywell BendixKing KLR 10 Installation Manual

Lift reserve indicator
Table of Contents

Advertisement

NOTE: The probe lock plate can face forwards or backwards and can be placed on either the left or right
side of the AOA probe depending on which pin hole is selected on the AOA probe.
 It may be necessary to remove material from the mounting plate that would prevent the AOA probe
from being installed at the proper angle. If the 50° (or less) angle of the AOA probe interferes with the
plate or in the final calibration steps, the AOA probe needs to be at a tighter angle, remove material
from the mounting plate only as required to allow enough range of motion for accurate calibration.
Drilling out the probe is not needed and will nullify the warranty
 Install the washer and nut onto the AN4 bolt and tighten it so the AOA probe will not move in flight.
 Use the included protractor to confirm that the AOA probe is at an initial 50° angle. If not, loosen the
nut enough that the probe lock plate can be backed out of the mounting bracket enough to rotate the
AOA probe until the correct hole is lined up, then reinsert probe lock plate and retighten bolt and nut.
 Optional, cut the electrical wires for the AOA heated probe to length and connect them to the heater,
polarity is not an issue, connect power to one lead and ground the other. Attach the shielding to a
suitable ground on one end of the wire only; this will prevent a ground loop.
 Cut the sense lines (at a 90° angle, verify NO burrs) to length so they may be easily attached to the
AOA probe but short enough so they will not kink when the mounting plate is secured to the wing.
Allow enough hose to re-position the AOA probe angle for final adjustments.
 Insert the lines firmly in the connectors, observe the 2 letters (B & W) on the side of the AOA probe,
"B"
(for Blue, Front Hole)
correctly installed, the line is inserted approximately 3/8 in. into the connector. Push hose in firmly
until a positive stop is felt.
P/N D201305000058
Rev 1 Jul 2013
Forward

Figure 3-11: Correct position of Probe lock plate

CAUTION:

Figure 3-12: Enlarging Mounting Plate Hole

TO BLUE LINE and "W" (for White, Bottom Hole) TO WHITE LINE. When
KLR 10 Installation Manual
Probe Lock
Plate
.
Remove
material at
this location
only
Installation
Page 3-9

Advertisement

Table of Contents
loading