8.9.4

Installation

Installed with DIN rail
1
Install the multi-drop connection module with its hook (1 place) using the DIN rail.
• Applicable DIN rail DIN46277 (width: 35mm)
(Install the DIN rail with screws at intervals of 150mm.)
Directly installed to panel
2
Install the multi-drop connection module to the panel using 4.5mm holes (2 places).
8.9.5

Caution for compliance with EMC Directive

Programmable logic controllers are open-type devices that must be installed and used within conductive
control boxes. Please use the Multi-Drop Connection Unit while installed in conductive shielded control
boxes. Please secure the control box lid to the control box (for conduction). Installation within a control box
greatly affects the safety of the system and aids in shielding noise from the Multi-Drop Connection Unit.
8 - 18
8.9 Serial Multi-Drop Connection Unit
8.9.4 Installation