14.3.26 Operation in parameter mode (P)

Details
Clearing all parameters
Parameter setting
(for A0J2HCPU)
Setting of latch range
Setting of step relay
Completion of setting
Parameter setting
(other than A0J2HCPU)
Setting of memory
capacity
M, L, S setting (other
than AnA, AnUCPU)
M, L, S setting
(AnA, AnUCPU only)
Timer setting
(other than AnACPU)
Timer setting
(AnACPU)
Counter setting
(AnACPU only)
Setting of latch range
WDT setting
WDT setting
(other than AnA, AnU)
Setting of I/O control
system (only for
A3HCPU and A3MCPU)
Completion of setting
(write)
14 - 76
14.3 MELSEC-A List Editor
14.3.26 Operation in parameter mode (P)
Purpose
Return the parameters to the
initial setting status.
Set the parameters for the
A0J2HCPU.
Select the latch range from
"No latch", "1/2 latch" and "All
latch".
Set the availability (S1536 to
2047) of the step relay.
When the parameter setting
is complete, write the PLC
CPU.
Set the parameters other
than A0J2HCPU.
Set the main sequence
program capacity and the file
register capacity.
Set the top device number
used in the latch relay/step
relay.
Set the top device number
used in the latch relay/step
relay/internal relay.
Set the top device used in the
low speed/high speed/
retentive timers.
Set the number of timers
used, the top device number
that stores the setting value
after T256, and the top
device used in the low speed/
highspeed/retentive timers.
Set the number of counters
used, and the top device
number that stores the setting
value after C255.
Set the range of the device
for latch setting.
Set the value of the watchdog
timer in the unit of 10 ms.
Set the I/O control system.
When parameter setting is
complete, write the PLC
CPU.
Procedures (key input sequence)
PARAM
1
PARAM
2
1)
1)
2)
1
GO
1)
2
GO
2)
Setting for multiple items is
also available.
1)
PARAM
2
1)
1
GO
Capacity
1)
1
Capacity
points
1)
1
1)
2
Top number of L
2
Top number of L
1)
1)
3
Top number of timer
1)
No. of timers
GO
3
GO
1)
4
No. of counters
1)
5
Top number of latch
End number of latch GO
1)
6
WDT value
GO
1)
GO
7
2)
Setting for multiple items is
also available.
GO
END
GO
2)
CLEAR
END
GO (End of writing is displayed.)
2)
END
(For main,
input unit: 1K step)
2)
GO
END
(For sub,
input unit: 1K step)
GO
2)
END
(For file register,
input unit: 1K point)
GO
Top number of S
GO
Top number of S
Top number of M
GO
2)
Top device for storage
of setting values
Top number of timer
GO
GO
Top device for storage
of setting values
GO
2)
(input unit: 10 ms)
2)
CLEAR
END
GO (End of writing is displayed.)
GO
2)
GO
GO
2)
2)
2)
GO
2)
GO
END