(2) Keyword settings of MELSEC-FX
On the communication detail setting screen of MELSEC-FX, registration, deletion, cancellation, or
protection of the keyword for FX series PLC can be executed.
MELSEC FX
10 - 10
10.2 Communication Detail Settings
10.2.3 Display contents of communication detail settings
Description
Select the connection method to the personal
computer.
Set the transmission speed when
communicating.
Set the data bit when communicating.
Set the stop bit length when communicating.
Set whether to execute or not the parity check
during communication. When executing, set the
type of the parity check.
Set the AT command for initialize the modem.
Touch the [Init.] button to initialize the modem.
Touch the [Cut] button to disconnect the line.
Setting range
Host (PC) / Host (Modem)
<Default: Host (PC)>
9600/19200/38400/57600/115200
<Default: 115200>
7bit/8bit <Default: 8bit>
1bit/2bit <Default: 1bit>
Odd/Even/None <Default: Odd>
<Default: AT & FE0%C0 & K0 &
D0W2S0=1>
-