(2) The following table describes the key functions displayed on the Entry Monitor screen.
Key switch
Activates the Quick test operation.
TEST
Subsection 14.2.8 Quick test operation of monitor devices
Switches the screen to the functional change menu screen to activate another monitor function or terminate the system
monitor function.
MENU
Subsection 14.2.9 Changing screens (common operation)
Switches the screen to the display format switching screen to change the value display format (DEC/HEX) on the Entry
Monitor screen or comment/no-comment display.
FORM
Subsection 14.2.7 Switching the display format (DEC/HEX) and comment/no-comment display
Switches the screen to the Device entry screen to enter monitor devices or delete or test entry devices.
Entering monitor devices:
SET
Deleting entry devices:
Test operation:
Scroll displayed information upward or downward by a line to display the preceding or next monitor device that is not
currently displayed. When five or more monitor devices are entered, these switches are available when their comments
are displayed.
: Scrolls information upward by a line.
: Scrolls information downward by a line.
(3) The following table below describes the range of display of items 1) to 10) displayed
No.
Item
connection
1)
Network No.
2)
Station No.
0 to 4: This item must be set only when the system is connected to multiple QCPUs. It is not necessary when
3)
CPU No.
Displays a comment (maximum number of characters: 16 one-byte characters)
4)
Comment
A comment is displayed when "DISPLAY" is selected for comment display on the display format switching
screen.
DW: Indicates that the device value is a 32-bit (two-word) module.
5)
Data range
Nothing displayed: Indicates that the device value is a 16-bit (one-word) module.
[Decimal number]
16-bit (one-word) module: Six digits (including a digit for a sign) are displayed. (Display example: -12345)
32-bit (two-word) module: Ten digits (including a digit for a sign) are displayed. (Display example: -123456789)
6)
Word device value
[Hexadecimal number]
16-bit (one-word) module: Four digits are displayed. (Display example: H AB12)
32-bit (two-word) module: Eight digits are displayed. (Display example: H ABCDE123)
: ON
7)
Bit device ON/OFF
: OFF
8)
Device No.
Up to eight devices can be monitored with regard to each CPU station number.
For further information about device numbers and names that can be entered:
9)
Device name
When no comments are displayed
Monitor display
10)
area
When comments are displayed
*1:
Indicates CC-Link connection (via G4).
14.2.11 Information displayed on the entry monitor screen and key functions
Subsection 14.2.5 Entering monitor devices (specifying monitor stations and devices)
Subsection 14.2.13 Deleting entry devices
Subsection 14.2.24 Test operation
Bus
Direct CPU
connection
FF
the system is connected to another CPU.
GT Designer 2 Version
Screen Design Manual
GT Designer 3 Version1 Screen Design Manual
:
Up to eight devices can be displayed.
:
Up to four devices can be displayed.
Function
Description of setting
Computer link
connection
0
F: When the host station is selected
0: When the master station is selected
1 to 64: When a local station is selected
(Fundamentals)
14.2 System Monitor
CC-Link connection
1
G4 *
14 - 27