Fault
CrST ‐ Cannot reset
Cause
The drive received a fault reset command when a run command was active.
Remedy
Turn off the run command then de-energise and re-energise the drive.
Fault
EF ‐ FWD/REV Run command input error
Cause
A forward command and a reverse command were input at the same time for
longer than 0.5 second.
Remedy
Examine the forward and reverse command sequence and correct the problem.
Fault
HCA ‐ High current alarm
Cause
The load is too heavy.
Remedy
Decrease the load for applications with repetitive starts and stops.
Contact us.
Cause
The acceleration time is too short.
Remedy
Contact us.
Fault
oH ‐ Heatsink overheat
Cause
The airflow is not enough around the drive.
Remedy
Check cubicle fan.
Cause
The drive internal fan has stopped.
Remedy
Check whether it should be replaced.
Fault
dWAL ‐ Warm up finish
Cause
Warm up completed.
Remedy
The pump has been warmed up completely, the inlet valve must be opened
manually.
Fault
dWA2 ‐ High temperature
Cause
The stator reaches 120 °C which is very hot for stator.
Remedy
Check cooling water.