Fault
oL2 ‐ Drive overload
Cause
The load is too large.
Remedy
Decrease the load.
Cause
The acceleration/deceleration times or cycle times are too short.
Remedy
Contact us.
Cause
Phase loss in the input power supply is causing the output current to change.
Remedy
Correct errors with the wiring for main circuit drive input power.
Make sure that there is no phase loss and repair problems.
Cause
Pump restarted when it is still hot.
Remedy
Wait for 60 minutes and restart the pump again. If the pump does not start, contact
us.
Fault
ov ‐ Overvoltage
Cause
The deceleration time is too short and too much regenerative energy is flowing
back into the drive.
Remedy
Contact us.
Cause
The acceleration time is too short.
Remedy
Contact us.
Cause
There are surge voltages in the input power supply
Remedy
Contact us.
Cause
The drive output cable or motor is shorted to ground (the current short to ground
is charging the main circuit capacitor of the drive through the power supply).
Remedy
Examine the motor main circuit cable, terminals, and motor terminal box, and then
remove ground faults.
Re-energise the drive.
Cause
The power supply voltage is too high.
Remedy
Decrease the power supply voltage to match the drive rated voltage.
Fault
oC ‐ Overcurrent
Cause
The load is too heavy.
Remedy
Contact us.
Cause
Overheating caused damage to the motor or the motor insulation is not
satisfactory.
Remedy
Measure the motor insulation resistance and replace the motor if there is electrical
conduction or unserviceable insulation.
A41870880_A
A41870880_A - Fault finding
Page 66
07/2021 - ©Edwards Limited