Edwards EXS Series Instruction Manual page 63

Dry screw vacuum pump
Table of Contents

Advertisement

Cause
Distances between housing and rotors is too small due to distortion of the pump.
Remedy
Affix and connect the pump free of tensions.
Cause
Rotors make contact with the housing.
Remedy
Contact us. Shut down the pump immediately.
Cause
Rotor is running untrue.
Remedy
Contact us. Shut down the pump immediately.
Cause
Oil thrower disc makes contact with the gear housing.
Remedy
Contact us.
Fault
Pump is losing lubricant
Cause
Oil level glasses leaky.
Remedy
Contact us.
Cause
Gear cover is leaky.
Remedy
Replace the O-ring of the gear cover.
Cause
Puddle under the motor, leak in the seal.
Remedy
Shut down the pump immediately. Contact us.
Cause
No lubricant leak is apparent.
Remedy
See
.
Fault
Oil gets too dark
Cause
Oil has been used up.
Remedy
Exchange the oil.
Cause
Pump gets too hot.
Remedy
See
Cause
Lubricant level is too high.
Remedy
Drain the lubricant down to the correct level.
Cause
Lubricant is ejected from the system.
Remedy
Check the system.
Cause
Pump is not standing horizontally.
Remedy
Place the pump correctly.
Cause
Pump has a gas leak towards the outside.
Remedy
Run a leak search and pinpoint leaks. If the leak is not at the oil‐fill plugs, return the
pump to the service.
A41870880_A
A41870880_A - Fault finding
Lubricant in the pump chamber
Pump gets too hot
on page 61. After the remedy of the fault, exchange the oil.
on page 64.
Page 63