Edwards EXS Series Instruction Manual page 69

Dry screw vacuum pump
Table of Contents

Advertisement

Cause
There is a loss of power.
Remedy
Use a better power supply.
Fault
Uv2 ‐ Control power undervoltage
Cause
There was a problem with the drive hardware.
Remedy
Re-energise the drive.
Contact us.
Fault
Uv3 ‐ Soft charge answerback fault
Cause
The relay or contactor on the soft-charge bypass relay is damaged.
Remedy
Re-energise the drive.
Contact us.
Fault
EF3 ‐ External fault(terminal S3)
Cause
Thermal overload relay tripped due to motor overheat.
Remedy
Check the cooling water.
Fault
dWFL ‐ High temperature warning
Cause
The stator temperature reaches 130 °C.
Remedy
Contact us.
Table 23 Inverter warning codes
Condition
bb - Baseblock
CrST - Cannot reset
EF - FWD/REV Run command input error
HCA - High current alarm
oH - Heatsink overheat
dWAL - Warm up finish
dWA2 - High temperature
Fault
bb ‐ Baseblock
Cause
An external baseblock command is entered through MFDI terminal S1 to S7 and
the drive output stopped as shown by an external baseblock command.
Remedy
Examine the external sequence and timing of the baseblock command input.
A41870880_A
A41870880_A - Fault finding
on page 69
on page 70
on page 70
on page 70
on page 70
on page 70
Page 69
on page 70
07/2021 - ©Edwards Limited