Feedback Option Module Set-Up - YASKAWA SGDV-OFB03A Product Manual

Feedback option module type 3 for sigma-5 and sigma-7 servopacks
Hide thumbs Also See for SGDV-OFB03A:
Table of Contents

Advertisement

Sigma-5 and Sigma-7 Series SERVOPACKs
10.3

Feedback Option Module Set-up

| | Feedback Option Module Type 3 - Manual version C - Revision 0 | en |
The use of this module and an encoder requires the transfer of a parameter file (exten-
sion .mgf) to the SERVOPACK.
The parameter file must be created by Yaskawa Europe GmbH. To do this, you must pro-
vide Yaskawa with all the information of the encoder (
Scale Configuration' page 47).
Then Yaskawa Europe GmbH generates 2 files:
n
an .mgf file, which is transferred to the SERVOPACK
n
a .txt file representing the summary
The parameter file (extension .mgf) must be written into the module via the SERVOPACK
using the SigmaWin+ software engineering tool.
SGDV SERVOPACK
The use of SigmaWin+ version 7.42 or higher is recommended.
Feedback Option Module Set-up
Ä Chap. 9 'Motor and Encoder /
Personal Computer
USB cable
Write the parameter file (extension .mgf)
via the SERVOPACK into the feedback
option module.
Set-up Procedure
SigmaWin+
Parameter file
57