Table 3-11: H.323 Dialog Box Parameters (Continued)
Field
Prefix
(cont.)
Refresh H.323
Registration Every
n Seconds
The following table describes the gatekeeper modes that can be
configured with each of the listed gatekeepers.
Table 3-12: Gatekeeper Interoperability
Gatekeeper Modes/
Types
Radvision MGK-100
Radvision ECS
VCON MXM
Cisco MCM
PathNavigator
Shading indicates the preferred configuration mode
Chapter 3 - Initial System Configuration
Description
When a firewall is used, two IP Network Services are
usually defined; one for the card that is connected to
the external network and the other one that includes
all the remaining cards (those connected to the
internal network).
The prefix is defined during the Network Service
configuration and is also assigned to the card when
assigning the circuit ID.
Enter the frequency in which the system informs the
gatekeeper that it is active by re-sending the IP
address and aliases of the IP cards to the
gatekeeper. (The conference details are not
registered.) If the IP card does not register within the
defined time interval, the gatekeeper will not refer
calls to this IP card until it re-registers. If timeout is
set to 0, re-registration is disabled.
Note: It is recommended to use default settings.
Board
Basic
Hunting
+
+
+
+
+
+
-
-
+
+
Pseudo
Register as
Gatekeeper
Gateway
+
+
+
+
+
+
-
+
+
+
3-39
Need help?
Do you have a question about the MGC-100 and is the answer not in the manual?