Diag-Level Variable Set To Max - Sun Microsystems Ultra 80 Service Manual

Hide thumbs Also See for Ultra 80:
Table of Contents

Advertisement

To return to the default setting:
ok setenv diag-level max
3.5.1

diag-level Variable Set to max

When the diag-level variable is set to max, POST enables an extended set of
diagnostic-level tests. The following code examples identify a typical serial port A
POST output with the diag-level variable set to max for 4-way, 2-way, and single
CPU configurations.
CODE EXAMPLE 3-1
CODE EXAMPLE 3-2
CODE EXAMPLE 3-3
Note – The following POST examples are executed with 450-MHz CPUs and
2.5 Gbytes of memory.
CODE EXAMPLE 3-1
Executing Power On SelfTest
0>
0>@(#) Sun U80(UltraSPARC-II 4-way) UPA/PCI POST 1.2.5 04/05/1999
09:42 AM
0>INFO: Processor 0 is master. CPU 450 MHz. 4304KB Ecache.
0>
0> <00> Init System BSS
0> <00> NVRAM Battery Detect Test
0> <00> NVRAM Scratch Addr Test
0> <00> DMMU TLB Tag Access Test
0> <00> DMMU TLB RAM Access Test
0> <00> IMMU TLB Tag Access Test
0> <00> IMMU TLB RAM Access Test
0> <00> Probe Ecache
0> <00> Ecache RAM Addr Test
0> <00> Ecache Tag Addr Test
0> <00> Ecache Tag Test
0> <00> Invalidate Ecache Tags
0>INFO: Processor 1 - UltraSPARC-II.
0>INFO: Processor 2 - UltraSPARC-II.
0>INFO: Processor 3 - UltraSPARC-II.
0> <00> Init SC Regs