Environmental Requirements - Sun Microsystems Ultra 80 Service Manual

Hide thumbs Also See for Ultra 80:
Table of Contents

Advertisement

A.3

Environmental Requirements

Environmental Requirements
TABLE A-3
Environmental
Temperature (with tape drive)
Temperature (without tape drive)
Humidity
Altitude (with tape drive)
Altitude (without tape drive)
Maximum dwells at extremes
Operating
41 to 104° degrees F
(5 to 40 degrees C)
41 to 113 degrees F
(5 to 45 degrees C)
5 to 90% at 104 degrees F
(40 degrees C) noncondensing
10,000 ft (3 km) at 86 degrees F
(30 degrees C)
10,000 ft (3 km) at 95 degrees F
(35 degrees C)
16 hr
Non-operating
-40 to 149 degrees F
(-40 to 65 degrees C)
-40 to 149 degrees F
(-40 to 65 degrees C)
5 to 93% at 104 degrees F
(40 degrees C)
40,000 ft (12 km) at 32 degrees F
(0 degrees C)
40,000 ft (12 km) at 32 degrees F
(0 degrees C)
16 hr