TABLE A–1
Parameter
AC Operating Range
Maximum VA Rating
Maximum Power Consumption
Maximum Heat Output
1.
Maximum input current with accessory connected to accesory outlet is 6A

Environmental Requirements

Table A–2 lists the environmental requirements for both operating and non-operating
environments.
TABLE A–2
Operating Environment:
Temperature
Humidity
Wet Bulb
Altitude
Vibration
Shock
Non-Operating Environment:
Temperature
Wet Bulb
SPARCclassic/SPARCclassic X/SPARCstation LX Service Manual ♦ Revision A, November 1993
154
Input Power Requirements and Power Dissipation
Environmental Requirements
Specification
87-264 Vrms, 47-63 Hz
153.8 VA
107.7 Watts
367.5 BTU/hr
10 to 40 ˚ C (50 to 104 ˚ F)
20 to 80% relative noncondensing
at 40 ˚ C (104 ˚ F)
25 ˚ C (77 ˚ F) maximum
0 to 3048 m (0 to 10,000 ft)
5-22 Hz, 0.01 inches p-p; 22-500 Hz, 0.25 g p-p
5 g pk, 10 msec 1/2 sine wave
20 to 75 ˚ C (-4 to 167 ˚ F)
46 ˚ C (115 ˚ F) maximum
(continued)