Table A-2 Environmental Requirements - Sun Microsystems SPARC classic Service Manual

Table of Contents

Advertisement

1. Maximum input current with accessory connected to accesory outlet is 6A
A.2
Environmental Requirements
TABLE A-2
environments.
TABLE A-2
Operating Environment:
Temperature
Humidity
Wet Bulb
Altitude
Vibration
Shock
Non-Operating Environment:
Temperature
Wet Bulb
Vibration
Shock
A-2
SPARCclassic/SPARCclassic X/SPARCstation LX Service Manual • November 1993
lists the environmental requirements for both operating and non-operating
Environmental Requirements
10 to 40˚C (50 to 104˚F)
20 to 80% relative noncondensing
at 40˚C (104˚F)
25˚C (77˚F) maximum
0 to 3048 m (0 to 10,000 ft)
5-22 Hz, 0.01 inches p-p; 22-500 Hz, 0.25 g p-p
5 g pk, 10 msec 1/2 sine wave
20 to 75˚C (-4 to 167˚F)
46˚C (115˚F) maximum
5-22 Hz, 0.02 inches p-p; 22-500 Hz, 0.5 g p-p
5 g pk, 10 msec 1/2 sine wave