Rs-485 - Dahua Technology DHI-ITC237-PW6M-LZF1050 User Manual

Access anpr camera
Hide thumbs Also See for DHI-ITC237-PW6M-LZF1050:
Table of Contents

Advertisement

Parameter
Barrier Always Open
On
Barrier Opening Control
Barrier Opening Config
Barrier Closing Config
Step 3
Click Confirm.

4.5.1.6 RS-485

You can configure the RS-485 serial protocol of the external device. After configuration, you can set
related parameters of the device on Web.
Select Setting > ITC > RS-485 > Trigger Mode.
Step 1
Step 2
Configure parameters.
1) DHRS.
Table 4-18 Barrier control parameter description
Description
Select it, and enable the function of barrier always open. Configure
the period of barrier always open. The barrier will not close during the
defined period.
Select it to enable barrier control, and configuration.
Triggers alarm through different modes, and remotely controls the
barrier opening and close.
● Every Trigger (Camera): Capture any vehicle, and output open
barrier signal.
● Every Plate (Camera): Capture any plated vehicle, and output
open barrier signal.
● Allowlist Open (Camera): Capture the vehicle which conforms to
allowlist or fuzzy matching, and then output open barrier signal.
● Order (Server): Platform sends command, and output open
barrier signal.
You can configure barrier opening control as Allowlist Open
(Camera), and Order (Server) at the same time. Allowlist Open
(Camera) takes priority.
● Relay-out: Alarm linkage output port. You can select anyone one
of the 3 ports.
● Signal Duration: The duration that the barrier opening or closing
signal lasts.
Figure 4-48 DHRS parameters
42
User's Manual

Advertisement

Table of Contents
loading

Table of Contents