144 Chapter 9 Configuring addressing conventions and messaging service defaults
Setting
Maximum pages per
fax item
Minimum length of
a Call Answering
Message
System time-outs
Setting
Command
Entry
Short Disconn
ect
Record
Copyright © 2007, Nortel Networks
.
Description
Maximum number of pages for any single fax item.
Default: 50 Valid range: 1–99
The number of milliseconds that must be recorded in
order for a call answering message to be saved as such.
Default: 500 Valid range: 0–10000
Description
The Command Entry time-out is used when the system is waiting
for a response from the caller. Set time parameters that, when
exceeded, prompt the system for a response.
Example: To prompt a caller after 2 seconds of non-response,
enter 2000.
Default: 3500 milliseconds Valid range: 1000–5000
The Short Disconnect time-out ends a call when the Command
Entry time-out is exceeded. Callers usually have several
opportunities to respond before the short disconnect time-out is
used. This time-out value is used when a caller disconnects
from a thru-dial service or voice menu.
Example: To configure CallPilot to disconnect a caller after 2
seconds of non-response, type 2000.
Default: 10000 milliseconds Valid range: 1000–30000
This time-out value is used when prompts are recorded for
menus, announcements, and thru-dial services. The system
disconnects the session when, during recording, the specified
length of silence is recorded.
Example: If the session is to be disconnected after 1 minute of
silence, enter 60.
Default: 120 seconds Valid range: 6–300