Install The Access Point Under-Seat - Extreme Networks AP560i Installation Manual

Hide thumbs Also See for AP560i:
Table of Contents

Advertisement

Install the Access Point Under-Seat

The maximum pressure is 4,000 psi.
Do not use pressure washer nozzles narrower than 15°.
Under bench, stadium riser mounted applications only
If the AP560i access point is mounted with a portion above the riser, ensure that there is a solid
backing plate covering the entire access point and service panel (EIO-03-SP) bottoms.
There must be a minimum of 1 inch of clear space below the mounted access point surface that is
closest to the floor.
Close the hole to the service panel if the access point extends above the stadium riser.
In areas where the temperature gets to freezing or below, apply a drop of anti-seize material to the
threads of the M6 screws (that hold the access point to the bracket) and M4 screws (that hold the
EIO-03-SP to the access point) prior to inserting the screw. Tighten the M6 screws to around 30
in-lbs. and the M4 screws to about 10 in-lbs.
Under seat applications only:
Tighten the EIO-04 M6 screws to around 30 in-lbs. and the EIO-03-SP M4 screws to about 10 in-lbs.
Install the Access Point Under-Seat
About This Task
The AP560i is used with the EIO-04 mounting kit for under-seat installation.
The EIO-04 under-seat mounting kit can be installed on a:
Procedure
1. Slope
2. Flat horizontal surface such as a stadium floor
3. Slope with EIO-GASKET to seal between the slope bracket and the riser
4. Flat vertical surface such as a stadium riser
20
ExtremeWireless™ AP560i Access Point
Note
The best practice is to install the EIO-04 under-seat mounting kit horizontally. The EIO-04
under-seat mounting kit can be installed on a 30-degree slope, a flat surface, or a stadium
riser.
Note
If installing the access point on a riser, the open bottom (excluding the conduit or cable
entry areas) of the service panel must be covered to minimize debris and water entry. It is
especially important to cover any portion of the service panel that extends above the riser.
Note
Leave approximately 1-inch between the outdoor access point bottom and the floor. The
gap will ensure that any water on the access point can drip off.
Install the Access Point