GE1 or GE2 Cable Connection Through the Metal
Sloping Bracket
Figure 22: Metal sloping bracket with the large conduit hole
Callout
A
Procedure
1. Using two anchors, nuts, and washers, attach the metal sloping bracket to the concrete floor.
2. Attach the conduit to the metal sloping bracket.
3. Bring in the GE1 or GE2 cable through the conduit hole.
4. Remove the gland cap, plastic cage, and the gasket from the GE1 port.
5. Connect the GE1 LAN cable through the GE1 port until it clicks into place.
If there is a GE2 connection, insert the cable through the GE2 gland until it locks into place into the
GE2 port.
52
ExtremeWireless™ AP560i Access Point
Description
Large conduit hole on the metal sloping bracket
Note
The conduit must extend out of the concrete by a minimum of 1/4 in. The maximum length
is below the slope surface.
Note
Put the removed parts onto the LAN cable to be attached to the access point later.
GE1 or GE2 Cable Connection Through the Service Panel
Base

Advertisement