 MAINTENANCE
(A) Airflow of air conditioner
IMPORTANT :
• Do not hit the fresh-air-filter. If the fresh-air-filter
becomes deformed, dust may enter into the air-
conditioner, which may cause damage and
malfunction for the machine.
• Do not use gasoline, thinner, or similar
chemicals to clean the fresh-air-filter because
damage to it may occur.
• Using gasoline, thinner, or similar chemicals to
clean the fresh-air-filter may also cause an
unpleasant odor in the cab when the system is
used next time.

6. Cleaning the recirculation air filter

WARNING
To avoid personal injury or death:
• When removing and attaching the recirculation-
air-filter, apply parking brake, stop the engine,
and remove the key.
Remove
the
thumbscrews
recirculation-air-filter.
(1) Cover
92
and
pull
out
the
(2) Thumbscrew
Normal use
1. Blow air from the opposite direction to the normal
air flow of the recirculation-air-filter.
Keep pressure of compressed air as follows.
Pressure of compressed air
(A) Airflow of air conditioner
IMPORTANT :
• Do not hit the recirculation-air-filter. If the
recirculation-air-filter becomes deformed, dust
may enter into the air-conditioner, which may
cause damage and malfunction for the machine.
• Do not use gasoline, thinner, or similar
chemicals to clean the recirculation-air-filter
because damage to it may occur.
• Using gasoline, thinner, or similar chemicals to
clean the recirculation-air-filter may also cause
an unpleasant odor in the cab when the system
is used next time.
Attach the filter and the cover as the following
illustration.
(1) Recirculation air filter
(2) Cover
EVERY 50 SERVICE HOURS
Under 205 kPa (2.1 kgf/ cm
(3) Thumbscrew
SSV65,SSV75
2
)