Electrical Outlet; Slow Blow Fuse; Replacing The Bolted Slow Blow Fuse - Kubota SSV65 Operator's Manual

Skid steer loader
Hide thumbs Also See for SSV65:
Table of Contents

Advertisement

FUSES
NOTE :
• The fuse of No.8, No.10 and No.20 are not set at
the factory. When using the attachments,
contact your KUBOTA dealer.

3. Electrical outlet

Max power is less than 120 W.
If you need another auxiliary electric, contact your
KUBOTA dealer for details.
(1) Electrical outlet

4. Slow blow fuse

Slow-blow-fuse protects the electrical circuits.
If the slow-blow-fuse is blown, check the electrical
circuits for trouble and then replace with a new
compatible slow-blow-fuse.
(See Replacing the bolted slow blow fuse on page 109)
(1) Slow blow fuse case
SSV65,SSV75
[Open cab model]
No.
Protected circuit
(A)
Main
(B)
Alternator
(C)
CRS
(D)
Glow CAB
[Closed cab model]
No.
Protected circuit
(A)
Main
(B)
Alternator
(C)
CRS
(D)
Glow CAB
5. Replacing the bolted slow blow
fuse
1. Disconnect the negative cord of the battery.
2. Remove the slow-blow-fuse-case.
(1) Slow blow fuse case
 FUSE
Fuse
Capacity
Remarks
type
60 A
Bolted
80 A
Bolted
SSV65
100 A
Bolted
SSV75
30 A
Plug-in
60 A
Plug-in
Capacity
Fuse type
60 A
Bolted
100 A
Bolted
30 A
Plug-in
60 A
Plug-in
109

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ssv75

Table of Contents