Checking The Evacuator Valve; Checking The Air Cleaner Warning Indicator; Checking The Dpf (Diesel-Particulate-Filter) Muffler - Kubota SSV65 Operator's Manual

Skid steer loader
Hide thumbs Also See for SSV65:
Table of Contents

Advertisement

 MAINTENANCE
2. Loosen and remove the cup, then clean the inside
surface with light oil.
3. Tighten up the cup.
(1) Screw
(2) Cup
(3) Shutoff-valve
(4) Float
(5) Drain plug
(6) Connector of water level
sensor
IMPORTANT :
• In reattaching the water separator, be careful
to keep off dust and dirt.
Be sure to purge the fuel system before
getting the machine restarted.
(See Purging of the fuel system on page 105)

13. Checking the evacuator valve

1. Open the evacuator valve.
2. Get rid of large particles of dust and dirt.
(1) Evacuator valve
NOTE :
• If
the
evacuator
damaged, the air cleaner does not function
properly. Accordingly, its element's service
life will get shorter.
86
(A) Close
(B) Open
(C) Loosen
(D) Tighten
valve
is
missing
or
14. Checking the air cleaner warning
indicator
If the air cleaner is clogged, the air cleaner warning
indicator on the instrument panel will light up.
If this should happen at high engine rpm, stop the
engine and clean the air cleaner element.
(See Checking the air cleaner element on page
90,Cleaning the air cleaner element on page 90 and
Cleaning the evacuator valve on page 91.)
(1) Air cleaner warning indicator
15. Checking the DPF (diesel-
particulate-filter) muffler
WARNING
To avoid personal injury or death:
• Before checking or cleaning the DPF muffler,
stop the engine and wait long enough until it is
cooled down.
1. Check to see if flammable material is deposited
around the DPF muffler.
If so, clean it out, otherwise a fire may result.
(1) DPF muffler
DAILY CHECKS
SSV65,SSV75

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ssv75

Table of Contents