 TROUBLESHOOTING
Error Code
Problem or Failure
Number
Auxiliary hydraulic control
E:019
system (Solenoid valve for
Leftward SW)
Electronic travel torque
E:020
management system
5 V power supply of the
E:021
sensor is short-circuited.
Fan rpm control solenoid
E: 022
valve cable broken
Error code number
appears if a jump-
"E:023"
er cable is connected to a
E:023
24 V battery or improper
device to jump start the
engine.
Hydraulic oil temperature
E:024
sensor error
E:026
CRS CAN communication
Solenoid for the ride con-
E: 027
trol is broken or short-
circuited.
Solenoid for the fan is bro-
E: 028
ken or short-circuited.
E: 029
Acceleration system
ECU CAN communication
E: 030
cable broken
The pressure sensor of
E: 031
the high speed mode is
broken or short-circuited.
Float mode selector sole-
E: 032
noid cable broken or short-
circuited
Forward detection pres-
E: 036
sure sensor (right) cable
broken
Forward detection pres-
E: 037
sure sensor (left) cable
broken
Requirement for the DPF
E:9000
regeneration.
114
Machine condition
Engine performance
Accelera-
Engine out-
Engine
tion limited
put limited
stopped
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Machine performance
The auxiliary-hydraulic-con-
trol-system is not turned on.
-
The other functions of the
machine are still operative.
The anti-stall solenoid fails to
-
function.
The machine fails to move.
The majority of systems fail.
The engine may be start-
ed and the machine may
-
move.
Do not try any jobs. Just
move the machine to a safe
place.
The fan speed is kept its
-
highest level.
Immediately stop using con-
nected device, and discon-
nect the 24 V battery. When
-
the engine gets restarted and
is running with no error code
number appearing, it means
there is no problem.
The traveling speed is kept
-
low speed.
-
-
-
The ride control stops.
The fan speed is kept its
-
highest level.
The machine is operative at
-
the idling rpm.
The traveling speed is kept
-
low speed and the fan speed
is kept its highest level.
The traveling speed is kept
-
low speed.
The float solenoid fails to
-
function and the float mode is
not turned on.
The back buzzer malfunc-
-
tions when the right wheels
move forward.
The back buzzer malfunc-
-
tions when the left wheels
move forward.
DPF must be regenerated,
-
but low engine rpm is unable
to start the DPF regeneration.
Provisional measure and
Correction
Immediately contact your lo-
cal dealer.
Immediately contact your lo-
cal dealer.
Immediately contact your lo-
cal dealer.
Immediately contact your lo-
cal dealer.
If the error code number
still appears, immedi-
"E:023"
ately contact your local deal-
er.
Immediately contact your lo-
cal dealer.
Immediately contact your lo-
cal dealer.
Immediately contact your lo-
cal dealer.
Immediately contact your lo-
cal dealer.
Move the machine to a place
suited for repair. Immediately
contact your local dealer.
Immediately contact your lo-
cal dealer.
Immediately contact your lo-
cal dealer.
Immediately contact your lo-
cal dealer.
Immediately contact your lo-
cal dealer.
Immediately contact your lo-
cal dealer.
Rev up the engine rpm and
start the DPF regeneration.
If the error code number
still appears, imme-
"E:9000"
diately contact your local
dealer.
(Continued)