EVERY 50 SERVICE HOURS
IMPORTANT :
• If the air suction is still inadequate or the color
of the exhaust gases is abnormal even after the
cleaning, replace the air-cleaner-element.
• Do not tap-clean the element. The element may
get deformed, which may adversely affect the
air cleaner performance.
4. Cleaning the evacuator valve
WARNING
To avoid personal injury or death:
• Wear eye protection.
• While cleaning, foreign matters may drop out of
the evacuator valve.
1. Open the rear door and engine hood.
2. Remove the dust-cover.
3. From behind the dust-cover, remove foreign matter
from the evacuator valve.
SSV65,SSV75
(1) Evacuator valve
(2) Dust cover
IMPORTANT :
• Failure to clean the evacuator valve may
shorten the air cleaner element's service life.
5. Cleaning the fresh air filter
Remove the fresh-air-filter.
(1) Fresh air filter
Normal use
1. Blow air from the opposite direction to the normal
air flow of the fresh-air-filter.
Keep pressure of compressed air as follows.
Pressure of compressed air
MAINTENANCE
(A) Clean from behind
2
Under 205 kPa (2.1 kgf/ cm
)
91