Checking The Air-Conditioner Condenser; Cleaning The Fuel Tank Cap - Kubota SSV65 Operator's Manual

Skid steer loader
Hide thumbs Also See for SSV65:
Table of Contents

Advertisement

 MAINTENANCE
explosive. Keep open sparks and flames away
from the battery at all times, especially when
charging the battery.
• When charging the battery, ensure that the vent
caps are securely in place if equipped.
• When disconnecting the cable from the battery,
start with the negative terminal first.
When connecting the cable to the battery, start
with the positive terminal first.
• Never check the battery charge by placing a
metal object across the posts.
Use a voltmeter or hydrometer.
When attaching the new battery, its positive terminal
faces to the rearward of the machine.
(1) Battery
(2) Positive terminal
• To slow charge the battery, connect the battery
positive terminal to the charger positive terminal
and the negative to the negative, then recharge in
the standard fashion.
• A boost charge is only for emergencies. The boost
charge will partially charge the battery at a high rate
and in a short time.
When using a boost-charged battery, it is necessary
to recharge the battery as early as possible.
Failure to recharge may shorten the battery's
service life.
• The battery is charged if the display of the indicator
turns green from black.
• When exchanging an old battery for a new one, use
a battery of equal specification.
Battery Type
GP31 (105E41R)
Direction for storage
• When storing the machine for long periods of time,
follow the following procedure.
1. Remove the battery from machine.
2. Adjust the electrolyte to the proper level.
Store the battery in a dry place out of direct
sunlight.
• The battery self-discharges while it is stored.
88
(A) Rearward of the machine
Volts
Capacity
12 V
85.3 A.H (at 5H.R)
Recharge the battery once every three months in
hot seasons and once every six months in cold
seasons.
18. Checking the air-conditioner
condenser
1. Check air-conditioner condenser to be sure it is
clean from debris.
(1) Air-conditioner condenser
NOTE :
• Air flows through the condenser, entering
through the top and exiting out the bottom.
As such debris may accumulate on the top
side. Remove the outside cover to gain
better access for cleaning.

19. Cleaning the fuel tank cap

1. Remove and disassemble the fuel tank cap.
2. Clean if the tank cap filter becomes dirty, and the
vent holes are clogged.
3. Assemble and reinstall the fuel tank cap.
(1) Fuel tank cap
(2) Tank cap filter
DAILY CHECKS
(3) Gasket
(4) Vent holes
SSV65,SSV75

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ssv75

Table of Contents