Bit 7
CONEN
This bit disables the automatic CR oscillation stop function to enable continuous oscillation function.
1 (R/W): Enable continuous oscillation
0 (R/W): Disable continuous oscillation
For more information, refer to "CR Oscillation Frequency Monitoring Function."
Bit 6
EVTEN
This bit enables external clock input mode (event counter mode).
1 (R/W): External clock input mode
0 (R/W): Normal mode
For more information, refer to "Operating Modes."
Note: Do not input an external clock before the RFCnCTL.EVTEN bit is set to 1. The RFINn pin is
pulled down to V
Bits 5–4
SMODE[1:0]
These bits configure the oscillation mode. For more information, refer to "Operating Modes."
RFCnCTL.SMODE[1:0] bits
0x3, 0x2
Bits 3–1
Reserved
Bit 0
MODEN
This bit enables the RFC operations.
1 (R/W): Enable RFC operations (The operating clock is supplied.)
0 (R/W): Disable RFC operations (The operating clock is stopped.)
Note: If the RFCnCTL.MODEN bit is altered from 1 to 0 during R/F conversion, the counter value
being converted cannot be guaranteed. R/F conversion cannot be resumed.

RFC Ch.n Oscillation Trigger Register

Register name
Bit
RFCnTRG
15–8 –
7–3 –
2
1
0
Bits 15–3 Reserved
Bit 2
SSENB
This bit controls CR oscillation for sensor B. This bit also indicates the CR oscillation status.
1 (W):
Start oscillation
0 (W):
Stop oscillation
1 (R):
Being oscillated
0 (R):
Stopped
Note: Writing 1 to the RFCnTRG.SSENB bit does not start oscillation when the RFCnCTL.
SMODE[1:0] bits = 0x1 (AC oscillation mode for resistive sensor measurements).
Bit 1
SSENA
This bit controls CR oscillation for sensor A. This bit also indicates the CR oscillation status.
1 (W):
Start oscillation
0 (W):
Stop oscillation
1 (R):
Being oscillated
0 (R):
Stopped
S1C17M01 TECHNICAL MANUAL
(Rev. 1.2)
level when the port function is switched for the R/F converter.
SS
Table 15.6.2 Oscillation Mode Selection
0x1
AC oscillation mode for resistive sensor measurements
0x0
DC oscillation mode for resistive sensor measurements
Bit name
Initial
0x00
0x00
SSENB
0
SSENA
0
SREF
0
Seiko Epson Corporation
Oscillation mode
Reserved
Reset
R/W
R
R
H0
R/W
H0
R/W
H0
R/W