Position to Element Test
This diagnostic positions the CHM in front of a tape drive, cleaning cartridge
slot, or a particular slot in the cartridge holder.
1. Select the Maintenance Menu by pressing
2. Select the Diagnostics Menu by pressing
3. Select Position to Element by pressing
The following screen is displayed:
Set Destination
↑ Increase
↓ Decrease
4. Select the element address where you want to position the CHM by
pressing
or
, then Enter.
The CHM moves in front of the element index you indicate. The system
displays a message similar to the following when the move is complete.
POSITION TO 3:
Status:
Complete
5. To run the test again with a different element index, press Escape to return
to the Diagnostics Menu, then repeat steps 4 and 5.
To abort the Position to Element diagnostic, press Escape and Enter.
SPARCstorage Library Menu Functions
or
, then Enter.
↑,
or
then Enter.
or
, then Enter.
0
4
4-19