Sun Microsystems SPARCstorage Library Installation And User Manual page 148

Hide thumbs Also See for SPARCstorage Library:
Table of Contents

Advertisement

C
Error
Description
Number
60
No label. The bar code scanner
could not read the bar code label
because there was no label on the
cartridge.
61
Read error. The bar code scanner
could not read the bar code label
because the label was unreadable.
62
Not present. The bar code scanner
could not read the bar code labels
because there was no data cartridge
magazine present.
65
DMA overrun. The bar code scanner
could not read the bar code label
because a Direct Memory Access
(DMA) overrun occurred.
67
DMA CH.2 Timeout. Controller
board error.
69
Label upside down. The bar code
scanner could not read the bar code
label because the label is upside
down.
70
L servo timeout. The CHM could
not reach its destination along the
long axis.
71
Parameter > limit. Firmware error.
72
Front door open. The front door is
open or the door solenoid is
malfunctioning.
C-4
Table C-1 Hardware Errors by Error Code (Continued)
Corrective Action
If the cartridge does not have a bar code label, place a label on the
cartridge. If there is a bar code label and it is correctly placed on
the cartridge, you may need to replace the bar code scanner.
If the cartridge does not have a bar code label, place a label on the
cartridge. If there is a bar code label and it is correctly placed on
the cartridge, you may need to replace the bar code scanner.
Install a data cartridge magazine. If installing a data cartridge
magazine does not remedy the problem, you may need to replace
the bar code scanner.
Make sure the tape library and the tape drives are not being used
by the host computer then reset the tape library. If this error still
occurs, replace the SMC controller card.
Make sure the tape library and the tape drives are not being used
by the host computer then reset the tape library. If this error still
occurs, replace the SMC controller card.
Replace the bar code label correctly.
Open the door. Look for anything that might be obstructing the
path of the CHM along the long axis. Make sure that the axis belt is
intact. If there are no obstructions and the belt is intact, you may
need to replace the SMC controller card. If replacing the SMC
controller card does not help, replace the tape library.
Make sure the tape library and the tape drives are not being used
by the host computer then reset the tape library. If the error still
occurs, replace the SMC controller card.
If the door is open, close the door. Lock the front door to resume
the tape library's operation. If the door is securely locked, replace
the front panel.
SPARCstorage Library Installation and User's Guide—June 1995