Table C-4 Hardware Error Sense Key (4h) ASC and ASCQ Values (Continued)
ASC
ASCQ
Byte 12
Byte 13
40h
89h
40h
90h
40h
91h
40h
92h
40h
A0h
40h
A2h
40h
A3h
40h
A4h
40h
A5h
40h
B0h
40h
B1h
40h
B2h
40h
B3h
40h
B4h
40h
B5h
40h
E4h
Error Codes
Display
Description
Panel
Number
77
The tape library was not in the correct control mode when
the command was executed.
To invoke commands from the Maintenance Menu, the
tape library must be in LCD Interface mode.
To run the SunDiag system exerciser, the tape library must
be in one of the Sequential modes (Sequential CTS1,
Sequential CTS2, or Dual Sequential).
Under normal operation, the tape library must be set to
SCSI Interface mode.
20
The gripper home sensor did not clear.
21
A gripper error occurred.
22
A gripper motion took longer than the maximum time
allocated for it. When motion functions do not complete in
the allocated time, current to the servo motors is cut off.
30
The CHM could not move along the short axis.
32
The motor on the short axis failed.
36
The tape library could not reset the servo chip for the short
axis.
37
The servo busy bit on the short axis failed.
73
The CHM could not reach its destination on the short axis.
40
The CHM could not move on the long axis.
41
The CHM could not return to home position on the long
axis.
42
The motor on the long axis failed.
46
The tape library could not reset the servo chip for the long
axis.
47
The servo busy bit on the long axis failed.
70
The CHM could not reach its destination on the long axis.
99
One of the motors is stalled. The tape library must wait
for it to cool down before operations can resume.
C
C-9