Setting: DP(ChartB)
* :This setting is usually unnecessary.
Items
Lead
Set the adjustment value of the
leading edge.
Main Scan
Sets the adjustment value of the
left edge.
Sub Scan
Set the adjustment value of the
trailing edge.
1.Measure the distance "A" from the leading edge to the black belt (inside) on the adjustment
original.
2.Enter the value solved in "Lead" using the the [+] [-] keys keys.
3.Measure the distance "B" from the left edge to the black belt (inside) on the adjustment original.
4.Enter the values measured in "Main Scan" using the the [+] [-] keys keys.
5.Measure the distance "C" from the leading black belt (inside) to the trailing black belt (inside)
on the adjustment original.
6.Enter the values measured in "Sub Scan" using the the [+] [-] keys keys.
7.Press the [Start] key to set the setting value.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
Contents
B
C
Original for adjustment
(P/N: 7505000106)
Figure 6-45
6-352
Setting range
14.0 to 16.0
15.0
14.0 to 16.0
15.0
265.0 to 269.0
267.0
A
2R4/2R5/2R6
Initial
Data
setting
variation
0.1mm
0.1mm
0.1mm