Method: DP FU (Chart A)
Automatic input of the target value
1.Set the specified original (P/N: 7505000107) face-up on the DP.
2.Enter maintenance item U411.
3.Select [Target].
4.Press the [ ] [ ] keys, [#] or [*] key to select [Auto].
5.Select [DP FU(ChartA)] using the [Up/Down cursor] key.
6.Press the [Start] key to read the barcode of the original chart and to start the automatic adjust-
ment.
7.When automatic adjustment has normally completed, [OK] is displayed.
* :When the error code "1e" or "1f" is displayed during the automatic adjustment in the DP
scanning and the barcode is not read, adjust the following after manually inputting the target
value.
Manual input of the target value
1.Enter the target values which are shown on the lower part of the front page of the adjustment
original (P/N: 7505000107) by executing the maintenance mode U425.
2.Set the specified original (P/N: 7505000107) face-up on the DP.
3.Enter maintenance item U411.
4.Select [Target].
5.Press the [ ] [ ] keys, [#] or [*] key to select [U425].
6.Select [DP FU(ChartA)] using the [Up/Down cursor] key.
7.Press the [Start] key to start Auto adjustment.
8.When automatic adjustment has normally completed, [OK] is displayed.
* :If an error occurs during auto adjustment, error code "NGXX" is displayed and operation
stops. In this case, check the error and execute the automatic adjustment again.
Error codes
Codes
00
Automatic adjustment success
01
Black band detection error
(Table scanning leading edge skew in the
sub-scanning direction)
04
Black band is not detected (Table leading
edge in the sub-scanning direction)
05
Black band is not detected (Table far end in
the main scanning direction)
06
Black band is not detected (Table near end
in the main scanning direction)
07
Black band is not detected (Table trailing
edge in the sub-scanning direction)
Contents
6-119
2R4/2R5/2R6-3
Corrective action
-
1. Set the original correctly and
execute the adjustment again.
2. Check lighting of the lamp or
replace it.