Setting: T2 Time Out
The T2 time-out time is specified as follows.
From CFR signal output to image data reception
From image data reception to the next signal reception
In ECM, from RNR signal detection to the next signal reception
1.By using [ ] [ ] or the numeric keys, change the setting value.
Sets the T2 time-out time.
2.Press the [Start] key to set the setting value.
Setting: Ta Time Out
Sets the time to start ringing for an operator through the external telephone after receiving a call
in the FAX/telephone automatic switching mode. (See figure 1-3-18). If either receiving a FAX
signal within this time or passing this time, the mode automatically switches to the FAX reception
mode. Execute when a reception error occurs when in the automatic FAX/telephone switching.
1.By using [ ] [ ] or the numeric keys, change the setting value.
Sets the Ta time-out time.
2.Press the [Start] key to set the setting value.
Setting: Tb1 Time Out
Sets the time to start sending the ring back tone after receiving a call as a fax machine in the
FAX/telephone automatic switching mode, (See figure 1-3-18). Execute when a reception error
occurs when in the automatic FAX/telephone switching.
1.By using [ ] [ ] or the numeric keys, change the setting value.
Sets the Tb1 time-out time.
2.Press the [Start] key to set the setting value.
Contents
Contents
Tb1
Tb2
Figure 6-24 Ta/Tb1/Tb2 time-out time
Contents
6-169
Setting
range
1 to 255
Setting
range
1 to 255 s
Ta
Setting
range
1 to 255
2R4/2R5/2R6
Initial
setting
69
Initial
setting
30
Initial
setting
20