Download Print this page

Kyocera TASKalfa 306ci Service Manual page 198

Hide thumbs Also See for TASKalfa 306ci:

Advertisement

(3) Maintenance modes list (35/40 ppm model)
Section
No.
General
U000 Printing Maintenance Report
U001 Exiting the maintenance mode
U002 Set Factory Default
U003 Setting the telephone number of the
service person
U004 Machine serial number
U010 Setting the maintenance mode ID
U018 Firmware self verification
U019 Firmware Version
Initializa-
U021 Initializes Memory
tion
U024 Formatting an HDD
U025 Firmware update (S)
U026 Retrieve the backup data
Drive
U030 Motor operation check
Paper
U031 Check the conveying switch
feed
U032 Clutch operation check
Convey-
ing
U033 Solenoid operation check
Cooling
U034 Paper timing adjustment
U035 Folio size setting
U037 Fan motor operation check
U051 Registration paper loop amount
adjustment
U053 Adjusting the motor speed
U059 Fan mode setting
Optical
U061 Lamp lighting check
U063 Shading position adjustment
U065 Adjusting the magnification for table
scanning
U066 Adjusting the table scanning timing
U067 Adjusting the table scanning center
line
U068 DP scanning position adjustment
Maintenance item
6-197
Outline
Printing the reports and exporting them to a
USB memory
Exiting from the maintenance mode
Initializing to the factory-default setting
Sets the telephone number of the service per-
son.
Display of the machine serial number and set-
ting
Setting the maintenance mode ID
Check the firmware falsification.
Displays the firmware version of the PWB
Initializing the backup RAM
Formats/configures the HDD
Updates the firmware
Retrieve the backup data
Drive the drive motor
Check the conveying switch On/Off
Check the paper conveying clutch operation
Drive the paper conveying and toner supply
solenoids
Adjusting the leading edge timing and the center
line
Sets the Folio paper length and width.
Drive each fan motor.
Adjusts the paper loop amount between the roll-
ers
Sets each motor's speed correction
Sets the drive mode of the conveying fan motor
Turns the exposure lamp on
Changes the scanner shading position
Adjusting the magnification for table scanning
Adjusting the leading edge timing for table scan-
ning
Adjusting the center line for table scanning
Adjusting the starting position for DP scanning
2R4/2R5/2R6

Advertisement

loading