Download Print this page

Kyocera TASKalfa 306ci Service Manual page 244

Hide thumbs Also See for TASKalfa 306ci:

Advertisement

U070
DP magnification adjustment
(Message: Adjust DP Motor Speed)
Contents
Adjusting the magnification for DP scanning.
Purpose
Adjusted if the magnification is incorrect in the auxiliary scanning direction when the DP is used
Adjustment
1.Press the [Start] key.
2.Press the [System Menu] key.
3.Place an original on the DP and press the [Start] key to make a test copy.
* :Check the duplex scanning by setting [Duplex] when test copying.
4.Press the [System Menu] key.
5.Select the item to adjust.
Items
Sub Scan (F)
Sub Scan (B)
Sub Scan
(CIS)
Duplex 1side
6.By using the [+] [-] keys or the numeric keys, change the setting value.
For the copy example 1, increase the value.
For the copy example 2, decrease the value.
* :When the setting value is increased, the image get longer, and it shortens when the setting
value is decreased.
7.Press the [Start] key to set the setting value.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
Contents
Adjusting the magnification for table scanning
Adjusts the 2nd side magnification in the sub
scanning direction when duplex scanning
Adjusts the 2nd side magnification in the sub
scanning direction when duplex scanning
(CIS)
Adjusts the 1st side magnification in the sub
scanning direction when duplex scanning
(CCD)
Original
example 1
Figure 6-35
Copy
Copy
example 2
6-243
2R4/2R5/2R6
Setting
Initial
range
setting
-25 to 25
-
-25 to 25
-
-25 to 25
-
-25 to 25
-3
Data
varia-
tion
0.1 %
0.1 %
0.1 %
0.1 %

Advertisement