Download Print this page

Kyocera TASKalfa 306ci Service Manual page 329

Hide thumbs Also See for TASKalfa 306ci:

Advertisement

U327
Cassette heater control setting
(Message: Set Cassette Heater Control)
Contents
Selects the cassette heater control setting.
Purpose
Selects the cassette heater control setting
Sets the cassette heater for the optional cassette.
Method
1.Press the [Start] key.
2.Select the item to set.
Items
On
Off
* :Initial setting: Off
* :Drum refresh is not executed at power-up when the cassette heater control is [On].
3.Press the [Start] key. Set the setting value.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
U332
Adjusting the black coverage coefficient
(Message: Adjust Coverage Size Calculation Rate)
Contents
Sets the coefficient of custom size with A4/Letter size. The coefficient set here is used to convert
the black ratio in relation to the A4/Letter size and to display the result in the service status page.
Purpose
Set the coefficient for converting the black ratio for custom sizes in relation to the A4/Letter size
Setting
1.Press the [Start] key.
2.Select the item to set.
3.By using the [+] [-] keys or the numeric keys, change the setting value.
Items
Rate
Set the coefficient for converting the black ratio
for custom sizes in relation to the A4/Letter size.
Mode
Switch full-color count and color coverage count
display
Level1
Sets low coverage threshold value
Level2
Sets middle coverage threshold value
4.Press the [Start] key to set the setting value.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
Sets the cassette heater control On (installed).
Sets the cassette heater control Off (not installed).
Contents
6-328
Contents
Setting range
0.1 to 3.0
0: Full color
1: by coverage
0.1 to 99.8
0.2 to 99.9
2R4/2R5/2R6
Initial set-
ting
1.0
0
1.0
2.5

Advertisement