8.2.5 System Settings – Position Control Parameter
The parameters on Position Control Parameter table set to specify input points as the positive and negative limits of
axis 1~ axis 6 channels. 12 limit points can be set at most. Axis No. 1~6 can also be set as Z phase triggers, home
function finish points and clear output selects or positive/negative limited position.
Axis1 (Y0.0/Y0.1) Positive/negative Limited Select ~ Axis 6 (Y0.10/Y0.11) Positive/negative Limited
Select.
Select the rising or falling edge trigger and X input point on the drop-down list.
Axis1 (Y0.0/Y0.1) Z Phase Trigger ~ Axis6 (Y0.10/Y0.11) Z Phase Trigger
Select the rising or falling edge trigger and X input point on the drop-down list.
Axis1 (Y0.0/Y0.1) Home Function Finish and Clear Output Select ~ Axis6 (Y0.10/Y0.11) Home Function
Finish and Clear Output Select
Select the rising or falling edge trigger and X input point on the drop-down list.
Axis1 (Y0.0/Y0.1) Positive/negative Limited Position ~ Axis6 (Y0.10/Y0.11) Positive/negative Limited
Position
Set up the number of pulses as the positive or negative limited position in axis 1~6; setting range is -
2147483647~2147483647.