Bat. Low Led Indicators Are On; Bat. Low Led Indicators Blinking Every 0.5 Seconds - Delta AS Series Operation Manual

Hide thumbs Also See for AS Series:
Table of Contents

Advertisement

Send Quote Requests to info@automatedpt.com
Connection lost in the mode of
current input 4 mA - 20 mA for the
0044
function card 1 (AS-F2AD) or for
the built-in AD input channel 1.
Connection lost in the mode of
current input 4 mA - 20 mA for the
0045
function card 1 (AS-F2AD) or for
the built-in AD input channel 2.
Connection lost in the mode of
current input 4 mA - 20 mA for the
0046
input channel 1 of the function
card 2 (AS-F2AD).
Connection lost in the mode of
current input 4 mA - 20 mA for the
0047
input channel 2 of the function
card 2 (AS-F2AD).
Connection lost in the remote
1500
modules
1502
Errors occurred in the remote
-
modules
150F
1800
Errors occurred in the extension
-
modules
180F
1900
Heartbeat errors occurred in the
-
slave in CANopen / ECAT
communication.
191C

12.2.5 BAT. LOW LED Indicators Are ON

The blinking happens when there is no battery (CR1620) or the power is low. Turn this option off in the HWCONFIG >
CPU > Device Setting > Show Battery Low Voltage Error CPU when you don't need the RTC function to keep track of the
current time (default is enabled).
Error
Code
(16#)
0027
Battery Low

12.2.6 BAT. LOW LED Indicators Blinking Every 0.5 Seconds

The blinking happens when RTC cannot keep track of the current time.
Error
Code
(16#)
RTC cannot keep track of the
0026
current time
0028
No response from RTC
Check the connection cable.
Check the connection cable.
Check the connection cable.
Check the connection cable.
Check the network connection cable.
Refer to Section 12.3.7 for more information on the
remote module error codes.
Refer to Section 12.3 for more information on the
extension module error codes.
1. Check the CANopen / ECAT connection cable.
2. Check if the specific slave is working properly.
Note: The last 2 digits of the error code represent the ID
number of the slave (convert hexadecimal to decimal).
Description
Change battery or turn this option off
Description
If the problem persists, contact the local authorized
distributors.
If the problem persists, contact the local authorized
distributors.
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Solution
Solution
SM27
H
SM27
H
SM27
H
SM27
H
SM30
V
SM30
V
SM10
V
-
V
Flag
Log
SM219
X
Flag
Log
SM218
V
SM217
V

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents