12.3.6 Troubleshooting for the Module AS00SCM as a Communication
Module
12.3.6.1 ERROR LED Indicators Are ON
The following error codes identify possible errors when the AS00SCM module is installed on the right side of the CPU
module and acts as a communication module.
Error
Code
16#1605
16#1606
12.3.6.2 ERROR LED Indicators Blinking Every 0.5 Seconds
The following error codes identify possible errors when the AS00SCM module is installed on the right side of the CPU
module and acts as a communication module.
Error
Code
16#1802
16#1803
16#1804
The following error codes can only be viewed with SCMSoft; when the following errors occur, they are not shown on the
LED indicators and the system does not send the error messages to the CPU module.
Error
Code
16#0107
16#0108
16#0201
Description
Hardware failure
The function card setting is incorrect.
Description
Incorrect parameters
Communication timeout
The UD Link setting is incorrect.
Description
The settings in HWCONFIG and manual
settings are not consistent with function
card 1.
The settings in HWCONFIG and manual
settings are not consistent for function card
2.
Incorrect parameters
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Solution
1.
Check that the module is securely installed.
2.
Install a new AS00SCM or if the problem persists,
contact the local authorized distributors.
1.
Check if the function card is securely installed.
2.
Install a new function card or if the problem persists,
contact the local authorized distributors.
3.
Check if the setting in HWCONFIG is consistent with
the function card setting.
4.
Install a new AS00SCM or if the problem persists,
contact the local authorized distributors.
Solution
Check the parameter in HWCONFIG. Download the
parameter again.
1.
Check whether the communication cable is
properly connected.
2.
Check if the station number and the
communication format are correctly set.
3.
Check if the connection with the function card is
working correctly.
1.
Check the settings of the UD Link.
2.
Check the warning settings in the PLC.
Solution
Check the settings in HWCONFIG and manual
settings for function card 1.
Check the settings in HWCONFIG and manual
settings for function card 2.
Check the parameter in HWCONFIG. Download the
parameter again.