Delta AS Series Operation Manual page 471

Hide thumbs Also See for AS Series:
Table of Contents

Advertisement

Send Quote Requests to info@automatedpt.com
Instance
Attribute
H'02
H'03
H'04
H'05
H'06
H'07
*1 Status Description (H'05)
Bit (s)
0
1
2
3
4-7
8
Access
Name
Rule
Device Type
Get
Product Code
Get
Revision
Get
Major Revision
Minor Revision
Status
Get
Serial Number
Get
Product Name
Get
Name
Owned
Reserved
Configured
Reserved
Extended Device Status
Minor Recoverable Fault
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Data Type
Values
UINT
H'0C
UINT
H'4000
STRUCT
--
USINT
H'01
USINT
H'01
WORD
H'00
UDINT
H'abcd
STRING
"AS300T"
Description
Does the device has an owner connection?.
0: No
1: Yes
0,Always OFF
Is the device configured?
0: No
1: Yes
0,Always OFF
0: Self-testing
1: Firmware update
2: At least one faulted I/O connection
3: No I/O connections established
4: Non-volatile configuration error
5: Major fault
6: At least one I/O connection in run mode
7: At least one I/O connection established, all in idle
mode.
8-15: Reserved
0: No minor recoverable fault detected
Description
Communication Adapter
Product Code
Revision of this device: Major /
Minor
Major Revision Range: H'01–H'7F
Minor Revision Range: H'01–H'FF
Status, refer to the following *1
table
The last 4 characters of the MAC
address, ab:cd
The maximum length of a product
name is 32 characters.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents