8.3.3 Scanning of the parameters

01 MONITOR
02 DRIVE INFO
03 STARTUP WIZARD
04 DRIVE CONFIG
05 LIFT

8.3.4 List of the last parameters modified

Pressing the CUST key, a list containing the last 10 parameters modified is accessed. One parameter is displayed at a
time and the list can be scrolled using the ▲ and ▼ keys.
To exit this list, press the ► key.

8.3.5 "FIND" function

Pressing the FIND key activates the function that makes it possible to access any parameter simply by entering the
parameter software number (PAR).
When the parameter reached by the "FIND" command is displayed, it is possible to navigate all the parameters forming
part of the same group using the ▲ and ▼ keys. Pressing the ► key returns to the "FIND" function.
To exit, press the ► key.

8.3.6 Parameter modification

To enter parameter modification mode, press the E key when the parameter to be modified is displayed.
To save the value of the parameter, following modification, press the E key again.
Note!
To save permanently,
To exit modification mode without saving the value, press the ESC key.
The operations to be carried out to modify the value depend on the type of the parameter, as described below.
Note!
For further information about the type of parameters displayed,
Numeric parameters
14 MOTOR DATA
15 ENCODER CONFIG
16 SPEED REG GAINS
17 REGULATOR PARAM
18 TORQUE CONFIG
When E is pressed to access modification mode, the cursor is activated on the digit corresponding to the unit.
Using the ◄ and ► keys, the cursor can be moved to all the digits, including trailing zeros that are normally not
displayed.
With the ▲ and ▼ keys, the digit under the cursor is increased or decreased.
Press E to confirm the modification or ESC to cancel.
Binary parameters (BIT type)
The parameter may assume only two states which are indicated as On-Off or 0-1.
11 DIGITAL OUTPUTS
14 MOTOR DATA
15 ENCODER CONFIG
16 SPEED REG GAINS
17 REGULATOR PARAM
Press E to activate modification mode. The entire line is displayed in reverse. Use the ▲ and ▼ keys to move from one
state to another. Press E to confirm the modification or ESC to cancel.
01 MONITOR
01/20
PAR:
Output current
0.0
see paragraph
8.3.7.
14 MOTOR DATA
01/26
PAR: 2000
Rated voltage
400
Def:
400
11 DIGITAL OUTPUTS
09/16

x8
Di g out 1X inversion
ADL300 • Quick installation guide - Specifications and connection
01 MONITOR
250
20/20
PAR:
Di g ital output X mon
00000000010001
A
0%
01 MONITOR
02/20
PAR:
Output voltage
0 V
see paragraph
8.3.2.
14 MOTOR DATA
01/26
PAR:
E
Rated voltage
000000400
V
Def:
400
11 DIGITAL OUTPUTS
PAR: 1430
09/16
E
Di g out 1X inversion
O f f
1400
252
0%
2000
v
11 DIGITAL OUTPUTS
PAR: 1430
09/16
Di g out 1X inversion
O f f
PAR: 1430
On
75

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Sieidrive adl300Sieidrive adl300 advancedSieidrive adl300 basicSieidrive adl300aSieidrive adl300b