Configuration Of The Display; Language Selection; Selection Of Easy/Expert Mode; Startup Display - gefran installationSIEIDrive ADL300 Quick Start Up Manual, Specification And Installation

Vector inverter for lifts with ynchronous/asynchronous motors
Table of Contents

Advertisement

8.3.8 Configuration of the display

8.3.8.1 Language selection

Menu 04 DRIVE CONFIG, parameter 04.19 Language select, PAR: 578,
default=English. This is used to set one of the languages available: English, Italian, French, German, Spanish and
Turkish.
01 MONITOR
02 DRIVE INFO
03 STARTUP WIZARD
04 DRIVE CONFIG
05 LIFT
Press E to confirm the modification or ESC to cancel.

8.3.8.2 Selection of Easy/Expert mode

Menu 04 DRIVE CONFIG, parameter 04.03 Access mode, PAR: 554.
Enables two methods of access to be configured:
Easy
(default) only the main parameters are displayed
Expert
for advanced users, all the parameters are displayed
01 MONITOR
02 DRIVE INFO
03 STARTUP WIZARD
04 DRIVE CONFIG
05 LIFT

8.3.9 Startup display

Menu 04 DRIVE CONFIG, parameter 04.9 Startup display, PAR: 574.
This is used to set the parameter that will be displayed automatically at drive power-on.
Entering the value -1 (default), the function is disabled and the main menu is displayed at power-on.

8.3.10 Back-lighting of the display

Menu 04 DRIVE CONFIG, parameter 04.10 Display backlight, PAR: 576. Sets lighting of the display:
On
the light of the display always stays on.
Off
(default) the light switches off approx. 3 minutes after the last key is pressed.

8.3.11 Alarms

The alarms page is displayed automatically when an alarm occurs.
j
Alarm
k
Undervoltage
l
Code:
m
Time:
27:45
(1) Alarm: identifies the alarm page.
RTN: indicates that the alarm has been reset; if the alarm is still active, nothing is displayed.
x/y: x indicates the position of this alarm in the list of alarms and y the number of alarms (the alarm with lowest x is
the most recent)
(2) Description of the alarm
(3) Sub-code of the alarm, provides other information in addition to the description
(4) Moment the alarm occurred in machine time.
The list of alarms is scrolled using the ▲ and ▼ keys.
Note!
For further information, see

8.3.11.1 Alarm reset

If the alarm page is displayed:
Pressing the RST key, the alarms are reset and all alarms that have been reset are eliminated from the list. If, after
this operation, the list of alarms is empty, the alarm page is closed. If the list is not empty, press the ► key to exit
the alarms page.
If the alarm page is not displayed:
Press the RST key to reset the alarms. If active alarms are still present following reset, the alarm page is opened.
04 DRIVE CONFIG
12/19

x6
Language sel e ct
English
Value: 0
04 DRIVE CONFIG
03/19
 
x2
Access mode
Easy
Value: 0
RTN : 1/2
0000H0
chapter
10.1.
ADL300 • Quick installation guide - Specifications and connection
04 DRIVE CONFIG
PAR:
578
12/19
E
Language sel e ct
English
Value: 0
04 DRIVE CONFIG
PAR:
554
03/19
E
Access mode
Expert
Value: 1
04 DRIVE CONFIG
PAR:
578
12/19
Language sel e ct
Italian
Value: 1
PAR:
554
PAR:
578
77

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Sieidrive adl300Sieidrive adl300 advancedSieidrive adl300 basicSieidrive adl300aSieidrive adl300b

Table of Contents