7.3 Connection diagrams
Note!
This chapter describes the typical wiring diagrams with reference to ADL300 drives with standard configuration.
7.3.1 Regulation potentials, digital I/O
52
Figure 7.3.1.1: Regulation potentials (ADL300A)
Shielded cable
43
Analog input 1
42
41
Analog input 2
40
Chassis
9
+24V
HW Enable
8
Digital input 1
n
Digital input n
0V(+24V)
DI COM
10
SAFETY EN+
SAFETY EN-
SAFETY OK1
SAFETY OK2
Chassis
Figure 7.3.1.2: Regulation potentials (ADL300B)
Shielded cable
43
Analog input 1
42
41
Analog input 2
40
Chassis
9
+24V
8
n
0V(+24V)
DI COM
10
SAFETY EN+
SAFETY EN-
SAFETY OK1
SAFETY OK2
Chassis
ADL300 • Quick installation guide - Specifications and connection
Analog output 1
Analog output 2
(Relay1)
(Relay n)
Digital Output 1
Digital Output n
Resettable fuse
Isolated power supply
for Inputs/Outputs
Relay 1
Relay 2
Relay 3
HW Enable
Relay 4
Digital input 1
Digital input n
Resettable fuse
Isolated power supply
for Inputs/Outputs
Shielded cable
47
0V
46
45
44
Chassis
49
+10V out
48
-10V out
56
57
n
n
29 DO-PS
+24V
27
LOAD
n
LOAD
DO CM
28
0V(+24V)
12
+24V_OUT
11
0V (24V)_OUT
57
56
55
54
53
52
51
50
12
+24V_OUT
11
0V (24V)_OUT